Siemon Cat 6A Patch Cord — 1 Metre

The Siemon Cat 6A Patch Cord (1 metre) is a factory-terminated, individually tested augmented Category 6 patch cable built for 10 Gigabit Ethernet environments. It is designed for use as the equipment cord or work area cord component within a compliant Cat 6A channel, connecting switches, patch panels, servers, and end devices in high-density rack and structured cabling installations.

The 1-metre length is specifically suited to short equipment room runs — top-of-rack switch-to-patch-panel connections, server-to-ToR switch uplinks, and back-of-rack device patching where minimal slack and tight cable management are priorities. Furthermore, when deployed as part of a complete Siemon Cat 6A channel alongside Z-MAX Cat 6A keystone jacks and Siemon Cat 6A horizontal cable, the patch cord contributes to a warranted end-to-end channel compliant with ANSI/TIA-568.2-D and ISO/IEC 11801 Class EA.


Performance and Bandwidth

The Siemon Cat 6A Patch Cord is rated to 500 MHz, meeting the augmented Category 6 performance standard. It supports 10GBASE-T (IEEE 802.3an) at the full 100-metre horizontal channel length when combined with a compliant Cat 6A horizontal cabling run. Additionally, it is backward compatible with Cat 6 and Cat 5e channels, making it deployable across mixed-generation infrastructure without performance penalty.

As a patch cord component, the Siemon Cat 6A Patch Cord must meet the more stringent insertion loss and crosstalk limits defined for connecting hardware in TIA-568.2-D — not just the horizontal cable limits. Each cord is individually factory tested against these parameters prior to dispatch. Consequently, performance consistency across units is verifiable, rather than dependent on installation technique.

Alien crosstalk (AXT) management is particularly important in Cat 6A patch cord design. The Siemon Cat 6A Patch Cord maintains controlled pair geometry and jacket diameter to limit PS-AANEXT contribution within a bundled cord environment — a relevant consideration in high-density patch panels where multiple cords run in parallel over short distances.


Construction and Connectors

The Siemon Cat 6A Patch Cord uses 26 AWG stranded bare copper conductors across four twisted pairs. Stranded construction provides the flexibility and bend tolerance required for patch cord applications, where cords are regularly connected, disconnected, and re-routed — unlike solid-core horizontal cable, which is intended for fixed permanent runs.

Each end is terminated with a Cat 6A-compliant RJ45 plug. The plug incorporates a moulded snag-resistant boot that protects the locking tab during installation and routine patching activity. In high-density environments where cords are bundled closely together, broken locking tabs are a common and avoidable failure mode. The snag-resistant design directly reduces tab breakage during extraction from congested patch panels.

The 1-metre Cat 6A Patch Cord has a slightly larger outer diameter than its Cat 6 equivalent — a structural characteristic of Cat 6A design necessary to achieve 500 MHz performance and alien crosstalk suppression. This must be considered when planning cable management density in patch panels and horizontal managers.


Channel Integration

The Siemon Cat 6A Patch Cord functions as either the equipment cord or work area cord within a TIA-568.2-D Cat 6A channel. The standard channel structure is as follows:

  • Up to 90 metres of Cat 6A horizontal cable
  • Two patch cords (equipment room and work area) with a combined maximum length of 10 metres
  • Termination at both ends via Cat 6A keystone jacks or panel ports

At 1 metre, this patch cord leaves up to 9 metres available for the complementary work area or equipment cord — providing flexibility in channel design without compromising the 10-metre combined allowance. When the complete channel uses matched Siemon Cat 6A components, it qualifies for Siemon’s end-to-end channel performance warranty and certified Class EA compliance.


Supported Applications

The Siemon Cat 6A Patch Cord supports the following applications within a compliant Cat 6A channel:

  • 10GBASE-T — 10 Gigabit Ethernet at full 100m channel (IEEE 802.3an)
  • 1000BASE-T — Gigabit Ethernet (IEEE 802.3ab), fully backward compatible
  • 100BASE-TX — Fast Ethernet
  • PoE++ — Up to 90W per port (IEEE 802.3bt Type 3/4)
  • PoE+ — Up to 30W (IEEE 802.3at)
  • Wi-Fi 6 and Wi-Fi 6E Access Points — High-power PoE++ WAP connections at patch panel
  • IP Surveillance — High-bitrate 4K/8K camera infrastructure patching
  • VoIP and Unified Communications — Low-latency structured cabling connections

Ideal Users

  • Data Centre and Server Room Technicians — The 1-metre length is optimised for top-of-rack and end-of-row patching where minimal cord slack is essential for airflow management and cable tray organisation. Factory testing eliminates the performance variability introduced by field-terminated cords in environments where 10G link reliability is critical.
  • Network Infrastructure Contractors — Deploying Siemon Cat 6A patch cords alongside Siemon horizontal cable and Z-MAX termination hardware completes the matched-component channel required for Siemon’s end-to-end warranty. On specification-driven and tender projects, warranty documentation at channel level is a standard handover requirement.
  • Enterprise IT Teams Managing High-Density Patch Panels — At 1 metre, the cord keeps equipment room patching neat and auditable. Colour-coded jacket options support structured identification schemes for VLANs, uplinks, and device types — reducing mispatching risk during MACs across large switch and panel installations.
  • Healthcare and Education Facilities with PoE++ Devices — IEEE 802.3bt support (up to 90W) enables the patch cord to carry full power delivery to high-draw connected devices including 802.11ax access points, PTZ cameras, and digital signage — within the same Cat 6A structured cabling plant used for data.
  • Colocation and Managed Service Providers — Short patch cords at 1 metre minimise inter-rack clutter in co-lo cage environments where space and cable management density directly affect operational efficiency. The snag-resistant boot reduces cord damage during frequent customer-driven patching changes.

Cable Specifications

Attribute Detail
Category Cat 6A (Class EA)
Standard ANSI/TIA-568.2-D / ISO/IEC 11801
Conductor 26 AWG Stranded Bare Copper
Pairs 4 Twisted Pairs
Shield Type Unshielded (U/UTP)
Connector Type RJ45 (8P8C), both ends

Performance Specifications

Attribute Detail
Rated Bandwidth 500 MHz
Supported Channel TIA-568.2-D Cat 6A / ISO/IEC 11801 Class EA
10GBASE-T Support Full 100m channel (IEEE 802.3an)
Impedance 100Ω (±15Ω)
AXT Management Controlled pair geometry for PS-AANEXT compliance
Test Standard Individually factory tested to TIA-568.2-D patch cord limits

Physical Specifications

Attribute Detail
Cable Length 1 metre
Jacket Material PVC / LSZH (optional)
Outer Diameter Approx. 6.5–7.5mm
Boot Type Snag-resistant moulded boot
Colour Options Blue, Grey, White, Yellow, Red, Green, Black (varies by SKU)
Operating Temperature 0°C to +60°C

Channel Integration Parameters

Attribute Detail
Maximum Combined Patch Cord Length 10 metres (equipment + work area cords)
Remaining Cord Allowance at 1m Up to 9 metres for complementary patch cord
Maximum Horizontal Cable Length 90 metres
Recommended Termination System Siemon Z-MAX Cat 6A Keystone Jacks / Patch Panels
Warranty Eligibility End-to-end Siemon channel warranty with matched components

Certifications

Certification Detail
TIA ANSI/TIA-568.2-D Cat 6A Patch Cord
ISO/IEC 11801 Class EA
IEEE 802.3an (10GBASE-T), 802.3bt (PoE++)
Flame IEC 60332 (LSZH variant)
Safety ETL/UL Listed
Environmental RoHS Compliant