D-Link Cat 6 UTP Copper Indoor Cable — 305m Reel (NCB-C6UGRYR-305)
The D-Link NCB-C6UGRYR-305 is a 23 AWG solid bare copper Category 6 UTP cable for fixed indoor structured cabling installations. It is manufactured to exceed the performance requirements of TIA/EIA-568C.2 and ISO/IEC 11801 Class E standards at 250 MHz, supporting Gigabit Ethernet (1000BASE-T) across the full 100-metre horizontal channel. The cable is ETL verified, CUL listed, and RoHS compliant, and is supplied on a 305-metre reel in grey.
D-Link is a globally established networking manufacturer with a structured cabling product line spanning switches, access points, and LAN cable. The NCB-C6UGRYR-305 is part of D-Link’s structured cabling solutions range — a Cat 6 solid cable designed for LAN infrastructure deployments in commercial offices, data centres, and enterprise environments where Gigabit connectivity and standards-verified performance are required at a straightforward price point.
Performance and Bandwidth
The D-Link Cat 6 cable is rated to 250 MHz and exceeds TIA/EIA-568C.2 Category 6 performance requirements across the full transmission parameter set. Verified electrical performance at 100 metres includes insertion loss of 19.8 dB, NEXT of 44.3 dB, PS-NEXT of 42.3 dB, ELFEXT of 27.8 dB, and ACR of 24.5 dB — all tested and verified by ETL against TIA/EIA-568C.2 limits, not just self-declared.
The cable supports the following Ethernet standards across a compliant 100-metre channel:
- 1000BASE-T — Gigabit Ethernet (IEEE 802.3ab) at full 100m channel
- 100BASE-TX — Fast Ethernet
- 10BASE-T — Standard Ethernet
- 10GBASE-T — 10 Gigabit Ethernet over shorter runs (approximately 55m channel)
The characteristic impedance of 100Ω (±15%) and nominal velocity of propagation of 69% are consistent with standard Cat 6 channel design parameters. Mutual capacitance of 5.6 nF/100m nominal and delay skew below 45 ns support VoIP, video streaming, and multimedia applications across the LAN without timing-induced signal degradation.
Cable Construction
The D-Link Cat 6 cable is built from the following components:
Conductors — 23 AWG (0.560mm nominal) solid bare copper, providing the lower attenuation per metre and correct IDC termination characteristics required for permanent horizontal fixed runs. Conductor resistance is below 9.38Ω/100m, with resistance unbalance not exceeding 5% — parameters that directly support reliable PoE power delivery alongside data transmission. Capacitance unbalance is controlled to below 330pF/100m, maintaining signal balance across the channel.
HD-PE insulation — High-density polyethylene insulation surrounds each conductor with a nominal insulation diameter of 0.970mm. HD-PE provides consistent dielectric properties across the operating temperature range, contributing to the stable impedance and velocity of propagation that Cat 6 performance at 250 MHz requires.
PE central cross separator — A polyethylene cross-filler maintains physical separation between the four twisted pairs, preserving pair geometry throughout the cable and reducing pair-to-pair crosstalk at high frequencies.
PVC UL94V-0 jacket — The outer jacket uses PVC compound rated to UL94V-0 — the standard vertical flame test rating for communications cables. This rating confirms that the jacket material self-extinguishes within defined limits when exposed to a flame source, meeting NEC and UL safety requirements for general indoor wiring. The cable diameter is 6mm nominal, and the jacket is grey — consistent with standard structured cabling colour conventions.
An LSZH jacket variant (NCB-C6UGRYR-305-LS) is available where halogen-free materials are required by project specification or building fire regulation.
Standards Compliance and Third-Party Verification
The D-Link Cat 6 cable is verified compliant with TIA/EIA-568C.2 by ETL — an independent third-party testing and certification body. ETL verification is a meaningful distinction from self-declared compliance: the cable has been tested by an accredited laboratory against the full TIA/EIA-568C.2 parameter set, and the results confirm that it meets or exceeds all Category 6 requirements. Furthermore, CUL listing confirms compliance with Canadian electrical safety standards under UL 444 for copper conductor communications cables.
This level of third-party verification supports structured cabling channel certification — a project deliverable on commercial fit-outs where the horizontal cable must be certified to Cat 6 performance as part of the installation handover documentation. Cables with only manufacturer-declared compliance cannot provide the same assurance in a third-party certified channel.
PoE Support
The D-Link Cat 6 cable supports PoE applications across a compliant channel. The solid bare copper conductors and controlled conductor resistance (below 9.38Ω/100m) provide the low DC resistance required for reliable PoE power delivery to connected devices. The cable supports:
- PoE (IEEE 802.3af) — Up to 15.4W per port
- PoE+ (IEEE 802.3at) — Up to 30W per port
- PoE++ (IEEE 802.3bt) — Up to 90W per port on compliant channel designs
For high-power PoE++ applications at longer run lengths, conductor temperature rise under sustained current load should be factored into channel design — particularly in dense cable bundles where heat dissipation is reduced. This is a channel-level consideration applicable to all Cat 6 cable, not specific to the D-Link product.
Installation Characteristics
The D-Link Cat 6 cable is supplied on a 305-metre reel. Maximum pulling force is 11.5kg, and minimum bend radius is four times the cable outer diameter during installation. The 6mm nominal outer diameter is consistent with standard Cat 6 cable sizing, compatible with standard conduit fill calculations, cable management finger ducts, and keystone jack termination tooling.
The cable terminates into standard Cat 6 keystone jacks, patch panels, and RJ45 field plugs using standard 110-style IDC tooling. No specialist equipment is required. The operating temperature range of -20°C to +70°C covers the full range of indoor building environments from unheated roof voids to climate-controlled data centres.
Supported Applications
The D-Link NCB-C6UGRYR-305 supports the following applications within a compliant 100-metre Cat 6 channel:
- 1000BASE-T — Gigabit Ethernet (IEEE 802.3ab)
- 100BASE-TX — Fast Ethernet
- 10BASE-T — Standard Ethernet
- 10GBASE-T — 10 Gigabit Ethernet over shorter runs (~55m channel)
- PoE / PoE+ — Up to 30W (IEEE 802.3af / 802.3at)
- PoE++ — Up to 90W (IEEE 802.3bt)
- VoIP and IP telephony — Converged network infrastructure
- IP Surveillance — Indoor IP camera cabling within structured cabling channels
- Wi-Fi Access Points — PoE-powered 802.11ac/ax WAP backhaul
- Building Automation and IoT — PoE-powered sensors, access control, and smart building devices
- Multimedia and video streaming — High-speed LAN for AV-over-IP and digital signage
Ideal Users
- Corporate and Enterprise Network Infrastructure Teams — The D-Link Cat 6 cable delivers ETL-verified TIA/EIA-568C.2 compliance and third-party certification support for commercial fit-out projects where channel performance documentation is a handover requirement. D-Link’s established brand presence in the networking market provides procurement confidence and straightforward after-sales support access.
- Structured Cabling Contractors on Standard Commercial Projects — The NCB-C6UGRYR-305 is a broadly deployed, standards-verified Cat 6 indoor cable suited to the majority of commercial horizontal cabling projects — offices, education facilities, healthcare buildings, and retail environments — where Gigabit connectivity and TIA/EIA-568C.2 compliance are specified. ETL verification supports channel certification and project handover documentation.
- SME and Mid-Market IT Infrastructure Managers — For organisations deploying or upgrading LAN infrastructure in office environments, the D-Link Cat 6 cable provides verified Gigabit performance at a straightforward price point backed by D-Link’s warranty and support infrastructure. PoE++ support accommodates current and future high-power device deployments on the same horizontal cabling plant.
- Data Centre and Server Room Infrastructure Designers — Within data centre and server room environments where horizontal runs connect patch panels to ToR switches in controlled indoor settings, the D-Link Cat 6 cable provides Cat 6 channel performance verified to TIA/EIA-568C.2. For 10G-to-the-rack infrastructure requiring full 100-metre 10G channel support, the Cat 6A variant should be specified instead.
- Education and Healthcare Facilities IT Teams — PoE and PoE++ device support — including 802.11ax access points, IP cameras, nurse call systems, and digital display panels — over a standard Cat 6 structured cabling plant reduces per-device installation cost compared to separately powered installations. The LSZH variant (NCB-C6UGRYR-305-LS) is available for installations where fire regulations require halogen-free cabling in ceiling voids and risers.
Cable Specifications
| Attribute | Detail |
|---|---|
| Model / SKU | NCB-C6UGRYR-305 |
| Category | Cat 6 (Class E) |
| Standards | TIA/EIA-568C.2, ISO/IEC 11801 Class E |
| Conductor | 23 AWG (0.560mm) Solid Bare Copper |
| Conductor Insulation | HD-PE (High-Density Polyethylene), 0.970mm OD |
| Pairs | 4 Twisted Pairs |
| Shield Type | Unshielded (U/UTP) |
| Central Filler | PE Cross Separator |
Performance Specifications
| Attribute | Detail |
|---|---|
| Rated Bandwidth | 250 MHz |
| Max Channel Length | 100 metres |
| 10GBASE-T Support | Up to ~55m channel |
| Characteristic Impedance | 100Ω (±15%) |
| Velocity of Propagation | 69% nominal |
| Mutual Capacitance | 5.6 nF/100m nominal |
| Conductor Resistance | < 9.38Ω/100m |
| Resistance Unbalance | 5% max |
| Capacitance Unbalance | < 330pF/100m |
| Delay Skew | < 45nS |
| Insertion Loss (at 100 MHz) | 19.8 dB/100m |
| NEXT (at 100 MHz) | 44.3 dB |
| PS-NEXT (at 100 MHz) | 42.3 dB |
| ELFEXT (at 100 MHz) | 27.8 dB |
| ACR (at 100 MHz) | 24.5 dB |
Physical Specifications
| Attribute | Detail |
|---|---|
| Jacket Material | PVC UL94V-0 (LSZH variant available: NCB-C6UGRYR-305-LS) |
| Jacket Colour | Grey |
| Cable Diameter | 6mm nominal |
| Reel Length | 305m |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -20°C to +80°C |
Installation Parameters
| Attribute | Detail |
|---|---|
| Maximum Pull Tension | 11.5kg (113N) |
| Minimum Bend Radius | 4× cable outer diameter |
| Conductor Type | Solid — permanent fixed runs only |
| Termination | Standard Cat 6 keystone jacks, patch panels, 110-style IDC tooling |
Certifications
| Certification | Detail |
|---|---|
| TIA | TIA/EIA-568C.2 Cat 6 — ETL Verified |
| ISO/IEC | 11801 Class E |
| Safety | CUL Listed (UL 444) |
| Environmental | RoHS Compliant |
| Flame | UL94V-0 jacket |











Reviews
There are no reviews yet.